Horizontal-type

The apparatus are widely used for cooling flushing acids in sulphuric production and also as a heater or cooler for other aggressive media. They are designed for cooling flushing acids in sulphuric production and can also be used for heating or cooling other aggressive media. The tube bundle and the tubes are similar to those of vertical-type apparatus. The heat exchange surface of the apparatus depends on the housing diameter, the number of tubes arranged, their diameter and effective length.

Technical data of shell-and-tube horizontal-type heat exchangers

Designation of a heat exchanger Din,

mm

 

L,

mm

Heat exchange surface Number of tubes, pcs. Number of baffles, pcs.
Fout Fout
HG-SТ400/4H37-8   400 2820 8 6 37 3
HG-SТ400/4H37-13 3820 13 9 5
HG-SТ400/4H37-17 4820 17 12 7
HG-SТ500/4H37-14   500 2950 14 10 61 3
HG-SТ500/4H37-21 3950 21 15 5
HG-SТ500/4H37-28 4950 28 20 7
HG-SТ600/4H37-21   600 3070 21 15 91 3
HG-SТ600/4H37-32 4070 32 22 5
HG-SТ600/4H37-42 5070 42 30 7
HG-SТ800/4H37-37   800 3250 37 26 163 3
HG-SТ800/4H37-56 4250 56 39 5
HG-SТ800/4H37-75 5250 75 53 7
HG-SТ1000/4H37-66 1000 3350 66 46 283 3
HG-SТ1000/4H37-98 4350 98 69 5
HG-SТ1000/4H37-132 5350 132 92 7
HG-SТ1100/4H37-81 1100 3480 81 57 349 3
HG-SТ1100/4H37-121 4480 121 85 5
HG-SТ1100/4H37-162 5480 162 113 7
HG-SТ1200/4H37-147 1200 4610 147 103 421 5
HG-SТ1200/4H37-195 5610 195 137 7
HG-SТ1400/4H37-206 1400 4720 206 142 583 5
HG-SТ1400/4H37-270 5720 270 190 7
HG-SТ1400/4H37-174 1400 4615 174 150 498 6
HG-SТ1400/4H37-232 5615 232 189 6

 

 